CDA HVG620 Manual do Utilizador Página 14

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 20
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 13
14
4. Turn the controls to maximum position then quickly to the minimum
position - make sure the flame does not extinguish.
5. Replace the knobs.
LPG to Natural Gas
Conversion
This hob can be converted from
propane operation at a nominal
inlet pressure of 37mbar or butane
operation at a nominal inlet pressure
of 28/30mbar to natural gas at 20mbar.
This conversion must only be carried
out by a competent person (i.e. a Gas
Safe registered fitter).
Required:
7mm AF nut spinner
Replacement injectors
NG identity plate
Burner LPG Injector Natural Gas Injector
Rapid 86 115
Semi-Rapid 67 97
Auxiliary 49 72
Triple ring/Wok 100 135
Vista de página 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 20

Comentários a estes Manuais

Sem comentários