45
- With SET held down, press “UP” to choose “Cr” parameter on display for
K-type thermocouple. (fig 54)
Note: If, instead of “Cr” we select “Fe” this corresponds to the black J-type
core thermostat (Iron Costanta).
Core probe thermostat
fig 52
fig 53
Electronic chamber thermostat adjustment
1/ ADJUSTMENT OF MAXIMUM STEAM TEMPERATURE (100º C).
Move blue switch 1 to ON . When the thermostat pin is turned the display must show 100. To adjust this
value, turn potentiometer P2 (fig 55).
Once adjusted, set switch 1 to OFF position.
2/ ADJUSTMENT OF MAXIMUM CONVECTION TEMPERATURE ( 30 270º C)
Mover blue switch 2 to ON. When the thermostat pin is turned the display must show a maximum
temperature of 270º C. To adjust this value, turn potentiometer P5 (this value is adjustable).
Once adjusted, set switch 2 to OFF position.
3/ ADJUSTMENT OF REAL TEMPERATURE INSIDE THE OVEN AND THE TEMPERATURE OF
THE ELECTRONIC THERMOSTAT DISPLAY.
Insert a calibrated thermostat in the oven and set the furnace to work in STEAM mode.
When it is seen that the oven is working at a stable temperature of 100º C with respect to the thermometer
inside, the temperature cut off at 100º C in steam mode is done with the electronic thermostat. The
adjustment of the temperature cut off at 100ºC and display is done with the potentiometer P3 with respect
to the thermometer inside the oven.
NOTES
The adjustment of the electronic thermostat is carried out in accordance with the temperature
reference indicated by the calibrated thermostat inserted indise the oven in order to control the real
temperature .