ϱϮΘΤΗ ΔϳέήΣ ΔΨπϤΑ ϞϤόΗ ϲΘϟ ΓΰϬΟϷ ϰϠϋΗ ΔϴδϜϋ ΓΩ ϞϳΪόΘΑ Ϥδ
έΎϴΘΧϻ ϊϣ ϰηΎϤΘΗ ΔϘϳήτΑ ίΎϬΠϟ ΎϫΪϟϮϳ ϲΘϟ ΔϗΎτϟ"ΩέΎΒϟ " ϭ"ϦΧΎδϟ."
ϦϴΰΟ Ϧϣ ΓΪΣϮϟ ϥϮϜΘΗ ΎϤϫ "ή
͋
ΨΒϤϟ "ϭ"ϒ
˷
ΜϜϤϟ " ϦϳάϠϟ ϰϠϋ ΎϤϬΘϴΒΜΗ ϢΘϳ
ϘΜΑ ΓΩϭΰϣ ΓΪΣϭ ΩΎϨγ· ΔΣϮϟ ϰϠϋ ξϴϘϧ ϲϓήρ ϲϓ ϡΪΨΘδΗ ςϴΤϤϟ ϰϠϋ
ΏϮ
ϰϠϋ ΔψϓΎΤϤϠϟ ΔΒγΎϨϣ ΔϴθΤΑϭ ˬϒϴϴϜΘϟ ΔϘτϨϤϟ ϲΟέΎΨϟ ϞϜϴϬϟ ϰϠϋ ΖϴΒΜΘϟ
ΔΟέΪΑ ΔϳΎϤΤϟ ΔΟέΩIP65.
ϮΤϧ
˱
ΎϬΠΘϣ ϥϮϜϴϓ ϒ
͋
ΜϜϤϟ Ύϣ ˬϲϠΧΪϟ ςϴΤϤϟ ϮΤϧ
˱
ΎϬΠΘϣ ή
͋
ΨΒϤϟ ϥϮϜϳ ˬϪϴϠϋ
ϲΟέΎΨϟ ςϴΤϤϟ.
ϮϤΠϣ Ϧϣ ˯ϮϬϟ ϒϴϴϜΗ ΓΰϬΟϷ Δϴδϴήϟ ˯ΰΟϷ ΔϋMAC-CWX/CRX
ΕΫ ΔϴϟΎΘϟ ΔϴΎΑήϬϜϟ ϊτϘϟ ϲϫ2GD ΕΎϘϴΛϮΗ ϰϠϋ
ΔϠλΎΣ ϲϫϭ
ˬΔϠϘΘδϣ.
• ΎϨΘϋϮϤΠϣ ˬϞϳΪΑ ϖϠϐϣ ςϏΎοMCE˭
• ΡϭήϤϟ ΕΎϛήΤϣ ˭
• ϲΒϟϮϟ ϒϠϤΑ ϡΎϤλΔϴδϜόϟ ΓΩϸϟ ΎϨΘϋϮϤΠϣ ˬMEV˭
• ˯ΎτϏ ϡϮϴϨϤϟϻ ΔϜϴΒγ Ϧϣ ωϮϨμϣϱϮΘΤϳ ϰϠϋ ΔϘϠόΘϤϟ ΓΰϬΟϷ
ϰϠϋϭ ϒ
˷
ϴϜϤϟ ϞϴϐθΗ ϖτϨϤΑ ϲΘϟ ΔϴϟΎΘϟ ΔϴΎΑήϬϜϟ ήϴϏ ˯ΰΟϷ
ήρΎΨϤϟ ϞϴϠΤΗ ΔϴϠϤόϟ ΖόπΧ :
• Ρϭήϣ˭
• ϊϣ ˬΔϔϨϋΰϣ ΔϳέΎτΑ ˬίΎϐϟϭ ˯ϮϬϟ ΪϳήΒΘϟ ΔϳέήΣ ΕϻΩΎΒϣ
ϡϮϴϨϤϟϻ Ϧϣ ϒϧΎϋίϭ ΔϴγΎΤϧ ΐϴΑΎϧ ˭
• ΔϨϴϤΛ ϚΎΒδΑ ϡϮΤϠϤϟ αΎΤϨϟ Ϧϣ ΔϋϮϨμϣ ΪϳήΒΗ ΓέΩ
. ΓέΪϟ
ϰϠϋ ϱϮΘΤΗ :ϴϔμΗ ίΎϬΟϒϴϔΠΗ ηήϣ ˬλ ˬ ΕΎϣΎϤ Ϧϣ
ΓέήΤϟϭ ςϐπϟ ΔΒϗήϣ ΓΰϬΟ ˬήϔλϻ αΎΤϨϟ˭
ΕΎϋϮϤΠϣ Ϧϣ ˯ϮϬϟ ΕΎϔϴϜϣ ΞϣΩ ϦϜϤϳ MAC-CWX/CRX ϊϣ
ϒϴϴϜΘϟϭ ΔϳϮϬΘϟϭ ΔΌϓΪΘϠϟ ϡΎψϧ ϦϳϮϜΘϟ ϚϟΫϭ ΡϭήϤϟ Ϧϣ ΔϠμϔϨϣ ΓΪΣϭ
)HVAC (Ϡϟϭ ΕΎϨϴΑΎϜϠϟ ϑήϐϟ ΓϮϬϤϟ ΔϟϮϤΤϤ)TVR( )ϰηΎϤΘϳ ΎϤΑ ϊϣ
Ϣϗέ ϪϴΟϮΘϟ
ήϴϳΎόϣEN 50381(.
ίΎϬΠΑ ή
͋
ΨΒϤϟ ΓΪΣϭ ΪϳϭΰΗ ϦϜϤϳ ΔΣϭήϤϟ Δϋήγ ϞϳΪΒΗ.
13
These latter will be mounted diametrically opposed on a
stainless steel panel completed with through fi xing holes
and suitable gasket, in order to maintain the IP65 degree of
protection. The evaporator module is oriented towards internal
environment in order to decrease relevent temperature; while
condenser module, oriented toward the outside, will dissipate
the heat.
The following electric components in 2GD execution (with
their own certifi cation) are main elements of MAC-CWX and
MAC-CRX air conditioners:
• Alternative Hermetic Compressor, our series MCE;
• Fans’ motors;
• Solenoid Valve of reversal device, our series MEV;
• Aluminium alloy Enclosure containing equipments relating to
the conditioner’s functional logic.There are also the following
non-electrical components (risks analysis carried out):
• Fans;
• Air/Refrigerant gas heat exchangers, fi nned battery type,
with copper tubing and aluminuim fi ns;
• Cooling circuit made of copper welded with precious alloy,
completed with: lamination capillary tube, mechanical
deidratation fi lter, brass valves, pressure and temperature
control devices.
The MAC-CWX/CRX series air conditioners can be
combined with a separated group of fans, in order to form a
HVAC system for cabinets and TVR (Transportable Ventilated
Rooms, according to EN 50381 standard). The evaporator
module can be provided with a commutation device for fan
speed.
Mac-Crx montaggio a soffi tto.
AC_CatHVAC_rv03@1-20#.indd 13AC_CatHVAC_rv03@1-20#.indd 13 12/05/14 14.2812/05/14 14.28