TIPS FOR INSTALLATION
Installation
CAUTION:
This appliance shall only be serviced by authorised personnel.
This appliance is to be installed only by an authorised person according to the current local
regulations and in observation of the manufacturer’s instructions.
Incorrect installation, for which the manufacturer accepts no responsibility, may cause
personal injury of damage.
Always disconnect the cooktop from mains power supply before carrying out any
maintenance operations or repairs.
WARNING !
We would point out that the adhesive which bonds the plastic laminate to the furniture must withstand
temperatures not less than 150 °C to avoid delamination.
– The appliance must be housed in heat resistant units.
– The walls of the units must be capable of resisting temperatures of 75 °C above room temperature.
490
50
(1)
270
300
510
A
Fig. 8
(1): at least 50 mm between the back side of the
cut-out and the back of the countertop.
A
45,2 mm
from top of countertop
to bottom metal cover
63,5 mm
from top of countertop
to terminal block