Fig.7
220-240 V single phase
32A 16A
Neutral
N
Brown
Green/Yellow
Blue
Black or grey
Blue
Live
L
Earth
Neutral
N
Earth
Brown
Live
L
220-240 V single phase
Neutral
N
Live
L
Earth
Brown
Green/Yellow
Blue
Black or grey
Brown
Green/Yellow
Blue
16A and 32A fuses dual supply 45A fuse single supply
Green/Yellow
Please note:
The mains cable must only be replaced by a qualified service
engineer and must be of equivalent or better rating (i.e. 2.5mm
²
,
HO5V2V2-F).
This appliance is intended to be connected to the mains supply with
a cable of cross section area 2.5 mm². A larger cable will not fit the
terminal connections.
The marking of the current rating of the fuse or circuit breaker protecting
this appliance should be marked on the socket outlet.
Assembly and electrical connection should be carried out by
specialised personnel.
When installing this product we recommend you seek the help of
another individual.