24
Fig.7
220-240 V single phase
32A 16A
Neutral
N
Brown
Green/Yellow
Blue
Black or grey
Blue
Live
L
Earth
Neutral
N
Earth
Brown
Live
L
220-240 V single phase
Neutral
N
Live
L
Earth
Brown
Green/Yellow
Blue
Black or grey
Brown
Green/Yellow
Blue
16A and 32A fuses dual supply 45A fuse single supply
Green/Yellow
Please note:
• The mains cable must only be replaced by a qualified service
engineer and must be of equivalent or better rating (i.e. 2.5mm
²
,
HO5V2V2-F).
• This appliance is intended to be connected to the mains supply with
a cable of cross section area 2.5 mm². A larger cable will not fit the
terminal connections.
• The marking of the current rating of the fuse or circuit breaker protecting
this appliance should be marked on the socket outlet.
• Assembly and electrical connection should be carried out by
specialised personnel.
• When installing this product we recommend you seek the help of
another individual.