CDA hg6310 Especificações Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
12
Total rated gas input : 7.5kW (hg6300)
8.0kW (hg6310 & hg6320)
Mains electrical voltage: 230 – 240Vac, 50Hz
Total rated electrical consumption: <1W
If Your Hob is Not Working
1. Check that the mains supply has not been switched o.
2. Check that the fuse in the spur has not blown.
3. Ensure that the burner components are not excessively soiled as
this can lead to ignition problems.
Burner Size Nominal Rating
(kW)
Simmer Rating
(kW)
LPG Flow Rate (lh
-1
)
G30 G31
Auxiliary 1.0 0.6 72.8 71.5
Semi-Rapid 1.75 0.68 127.3 125.4
Rapid 3.0 1.2 218.8 214.8
Triple 3.5 2.6 277 272
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 23 24

Comentários a estes Manuais

Sem comentários