Mounting your Extractor
The extractor can be mounted in one of two ways:
To fasten the product to the underside of a bridging cabinet:
To fasten the product to the underside of a bridging cabinet remove the grease filter cover and screw the hood directly to the
cabinet using appropriate wood screws (Not supplied).
To mount the hood on to a wall, proceed as follows:
1. Drill four holes as shown in the diagram below, corresponding to positions B and Z on the diagram. Note that the size of
the holes dependant on the wall fixings you will be using.
2. Insert the wall fixings into the hole (B) and tighten the fixing screw, leaving about 2 to 3mm proud of the wall. Insert wall
fixings in to the position Z for use later.
3. Hang the hood on the fixing screws and secure the hood in position using two screws fixed to the wall fixings in position Z.
Ducting and Ventilation
For best performance and lowest noise output, we recommend the use of 125mm ducting. You can also use 100mm ducting
but this will reduce performance.
If the extractor is to be used in recirculation mode, ensure that the lever (E) on the base of the motor is turned from
position A (ducted) to position F (re-circulation), as shown in Fig 2.