TIPS FOR INSTALLATION
Location
The appliance may be installed in a kitchen, Kitchen/diner or a bed sitting room, but not in a room or
space containing a bath or a shower.
– The appliance must not be installed in a bed-sit room of less than 20m
3
.
The appliance is designed and approved for domestic use only and should not be installed in a commercial,
semi commercial or communal environment.
Your product will not be guaranteed if installed in any of the above environments and could affect any
third party or public liability insurances you may have.
This hob should only be installed by a qualified installer. Failure to observe this rule leads to cancellation
of the guarantee.
The appliance must be installed correctly, in compliance with the regulations in force and following the
manufacturer's instructions.
– Any repair or maintenance must be performed with the appliance switched off.
– These appliances have been designed and manufactured to be fitted into heat-resistant units.
– These hobs are designed to be fitted into 600mm deep kitchen units.
The unit walls must not be higher than the working surface and must withstand a temperature of 105°C
above room temperature.
– Avoid installation near inflammable materials (e.g. curtains).
Ventilation Requirements
The appliance should be installed into a room or space with an air supply in accordance with BS 5440-2:
2000.
For rooms with a volume of less than 5m
3
- permanent ventilation of 100cm
2
free area will be
required.
For rooms with a volume of between 5m
3
and 10m
3
a permanent ventilation of 50cm
2
free area will be
required unless the room has a door which opens directly to the outside air in which case no permanent
ventilation is required.
– For rooms with a volume greater than 10m
3
- no permanent ventilation is required.
Important !
Regardless of room size, all rooms containing the appliance must have direct access to the
outside air via an openable window or equivalent.
Where there are other fuel burning appliances in the same room, BS 5440-2: 2000 should be consulted
to determine the correct amount of free area ventilation requirements.
The above requirements allow also for use of a gas oven and grill but if there are other gas burning
appliances in the same room, consult a qualified engineer.