CDA HG9320 Manual de Serviço Página 16

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 20
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 15
16
Conversion to Natural Gas or LPG
Replacing the Burner Injectors
– Remove the pan supports, the burner caps and flame speaders.
Using a wrench, substitute the nozzle injectors J” (Figs. 19 - 20) with those most suitable for the kind
of gas for which it is to be used.
The burners are conceived in such a way so as not to require the adjustment of the primary air.
J
J
Triple Ring
burner
Auxiliary,
Semi-Rapid
and Rapid
burners
Fig. 19 Fig. 20
Table for the Choice of the Injectors
Cat: II 2H 3+
Burners Nominal
Power
kW
Reduced
Power
kW
G30 - 28-30 mbar
G31 - 37 mbar
G20 - 20 mbar
Ø Injector
1/100 mm
Ø Injector
1/100 mm
Auxiliary (A) 1,00 0,30 50 72 (X)
Semi-Rapid (SR) 1,75 0,45 65 97 (Z)
Rapid (R) 3,00 0,75 85 115 (Y)
Triple Ring (TR) 3,50 1,50 95 135 (T)
Vista de página 15
1 2 ... 11 12 13 14 15 16 17 18 19 20

Comentários a estes Manuais

Sem comentários