Bond Module
40 Copyright © 2013 EVG
4.3.3 General
4.3.3.1 Flags
With this recipe command the wafer separation flags between the top
and bottom wafer can be pulled out (either all or certain ones).
For pulling the flags individually, the proper check box has to be
activated and the command has to be inserted three times in the recipe
(each time with a different check box activated).
Figure 32 - Flags
4.3.3.2 Wafer Bow On
This recipe step is available if there is a wafer bow function equipped on
the piston of the bond chamber.
Using this recipe step will activate the wafer bow function.
If activated, the ceramic pin will contact the wafers first when the piston
moves down inside the bond chamber.
No parameters necessary.