Monthly Maintenance
Copyright © 2012 EVG 125
5
5
5.19.2 Bottom side
Figure 125 - Over Temperature Switch Bottom Side
Disconnecting the over temperature sensor must disable the chamber
check SW input Low IO General “XCO161 #11”
Remove over temperature sensor and heat it with a hot air gun. Over
temperature sensor must shut off check SW input Low IO General
“XCO161 #11”
Top side at 63°C
Bottom side at 125°C