Quarterly Maintenance
Copyright © 2012 EVG 129
6
6
6.2.3.2 Thermo Chuck
The thermo chuck maintenance has to be done weekly.
Figure 131 - Thermo Chuck
6.3 Adjust heater offset
6.3.1 Short Description
6.3.1.1 Temperature offset:
The thermocouple sensors used on EVG bonding systems are very
accurate, but still have a small measurement tolerance. That is why the
same temperature reading on different EVG bonding machines may
lead to a small temperature difference from bonder to bonder.
In order to compensate this difference and to run one production
bonding recipe on different machine with the same result, a temperature
offset setting is possible which can be adjusted individually from
bondchamber to bondchamber.
This setting adds an individually adjustable offset in the range of +5 to -
5°C to the set point in the recipe. The status window on the screen
shows the temperature including the offset.
e.g.: If a 380°C heating set point is adjusted in the recipe and the offset
is defined with +3°C, the heaters reach a temperature of 383°C
according to the thermocouple in the bonder and will show 383°C in the
status window and in the recorder file.