Gun Solenoid Wiring
(con
ti
nued)
Installation 3-13
WARNING: Burns. Unexpected gun firing can occur during
! PC40 installation.
The
firing can be a response to trigger
signals caused by foreign objects blocking the sensors, and
by intentional and unintentional triggering that can occur
during maintenance. Nordson recommends that you
install
quick-disconnect solenoid leads. Disconnect the leads
during installation
to
disable the solenoid. Users
may
want to
provide an additional measure of safety by disabling the
trigger.
4. Use 16-18 gauge
electrical wire (customer supplied) to make the
connections shown in Table 3.4.
See Figure 3.9 for the location of
terminal block
P2.
Table 3.4 - Solenoid Pin Connections
and
Functions
Solenoid ConnectionC
1
> PC40 Terminal Block-Pin Connection Function
Solenoid
#1:
Ground (if present)
P2-3 ("GROUND") (
2
)
Solenoid ground
One lead to PC40 P2-5 ("VALVE 1 - RETURN") Solenoid return connection
One lead
to
PC40 P2-6 ("VALVE 1")
Solenoid source connection
Solenoid
#2:
Ground (if present)
P2
-3 ("GROUND") (
2
)
Solenoid ground
One lead
to
PC40 P2-7 ("VALVE 2 - RETURN") Solenoid return connection
One lead to PC40 P2-8
("
VALVE 2") Solenoid source connection
Solenoid
#3:
Ground (if present)
P2-3 ("GROUND") (
2
)
Solenoid ground
One lead to PC40
P2-9 ("VALVE
3 - RETURN") Solenoid return connection
One lead to PC40
P2-1 0 ("VALVE
3") Solenoid source connection
Solenoid
#4:
Ground (if present)
P2-3 ("GROUND") <
2
>
Solenoid ground
One lead to PC40
P2-
11
("VALVE
4-
RETURN") Solenoid return connection
One lead to PC40
P2-12 ("VALVE 4")
Solenoid source connection
{I) Some patterns require more than eight transitions. Two channel outputs can be connected in parallel to a
solenoid. Then you can program both channels' transition
va
lues
in
sequence for a total
of
16 transitions.
(
2
l If all four solenoid grounds are present, they will
not
all fit onto P2-3. Connect all the grounds together using a
connector, wire nut, etc. before connecting to