3-20 Installation
Mounting
Nordson
Sensors
(continued)
PIN 108 389A
57·28 1/93
Mounting
Retroreflectlve Sensors
NOTE:
To avoid unwanted trigger signals, make sure that there are no
objects other than the substrate that pass between the emitter/receiver
and the reflector during line operation.
NOTE:
Make sure that the emitter/receiver and reflector are mounted
no more than 7
ft
(2.13 m) from each other {polarized model)
or
no
more than
15ft
{4.5
m)
from each other {non-polarized model).
1.
Check the intended mounting position to ensure that there is enough
space
to
mount the sensor(s) and bracket(s). See Figure 3.
11,
Figure 3.12, and Figure 3.13
2.
Check the intended mounting position
to
make sure that there are no
objects other than the substrate that
will pass between the sensor
and substrate during
line operation.
3. Locate the emitter/receiver bracket so that it is no further from the
reflector than
a. 7
ft
(2.13 m) for the polarized model,
or
b.
15ft
(4.5
m)
for the non-polarized model.
4.
Securely connect the emitter/receiver bracket
to
the mounting
surface. Excessive movement
or
vibration can result in
intermittent
or
fa
lse operation caused by loss
of
alignment
to
the
substrate.
5. Using the two mounting bolts provided with the bracket, secure the
emitter/receiver to the bracket (Figure 3.13).
6.
Secure the reflector to the mounting surface opposite the
emitter/receiver.
7.
Route
the
sensor leads through water-tight conduit (for an lP-54
enclosure rating) and the strain
relief connector and into the PC40.
8.
Skip to "Nordson Photosensor Wiring Connections."
C>
Nordson Corporalion 1993
Aft Rtghts
ReseNed