Mounting Nordson Sensors
(contin
ued)
C Nordson Corpora
Don
1993
AU
R•ghts Re
sOlVed
Installation 3-19
Mounting
Opposed
Sensors
NOTE:
To
avoid unwanted trigger signals, make sure that there are
no
objects other than the substrate
that
pass between the emitter and
receiver during line operation.
Also, make sure that the emitter and
receiver are mounted no more than
10ft
(3 m) from each other.
1. Check the intended mounting position to ensure that there is enough
space to mount the sensor(s} and bracket(s}.
See Figure 3.11,
Figure 3.
12
, and Figure 3.13
2. Check the intended mounting position to make sure that there are no
objects other than the substrate that
will pass between the sensor
and substrate during
line operation.
3. Locate the emitter bracket
so
that the emitter is no further than 1 0 ft
(304.8 em) from the substrate.
4. Securely connect the emitter bracket to the mounting surface.
Excessive movement or vibration can
result in intermittent or false
operation caused by loss
of
alignment to the substrate.
5.
Securely connect the receiver bracket to the mounting surface.
6. Using the two mounting
bo
lts provided with the bracket
s,
secure the
emitter and receiver to their respective brackets (Figure 3.13).
7. Route the sensor
leads through water-tight conduit (for an
IP
-54
enclosure
rating) and the strain relief connector and into the PC40.
8. Skip to "Nordson Photosensor Wiring Connections."
PIN
1
08
38911.
57·
28
1/93