5-2 Troubleshooting
4. Guns Not Firing
Problem
PC40
status
LED red.
(NOTE:
It is normal for
this LED to light red at
unit power-up. After a
brief
self-test, it will
light
green.)
PC40
status
LED
dark
.
PC40
output
LED(s)
lighting.
PiN 108 389A
57
·2
8 1/93
Possible Reason
Selecting an unconfigured
memory via remote memory
select line.
PC
40 has
fa
iled internal
diagnostics check.
Power switch in OFF position.
Defective fuse.
No input power to PC40.
Incorrect
or missing wi
re
connections in PC40.
PC40
failure.
No applicator powe
r.
Insufficient system pressure.
Incorrect or missing wi
re
connections in PC40.
Gun and/or solenoid problem.
Corrective Action
Select configured memory
or
make unconfigured memory
available.
Replace
unit; contact your
Nordson representative.
Move switch to
ON postion.
Check;
replace
if
necessary.
Turn power
ON
Turn power to PC40 OFF;
remove front assembly and check
connections.
Replace; contact Nordson
representative.
Check that applicator breaker
switch
ON; check
for
input line
voltage
if
necessary.
Check for proper pressure and
adjust if necessary.
Select Test mode (press and hold
Nordson oval until arrow on LCD
points to
"TESr
; press LEFT or
RIGHT
to
select channel; press
SET and check for 240 VAC
or
at
solenoids; if
no
power present,
turn PC40 power
OFF,
remove
front
assembly, and check output
connections.
Follow troubleshooting procedure
in gun and/
or
solenoid manual.
Refer to
Sec.
4,
w
conf
igure
Mode".
Figure 5.1.
Applicator
manua
l.
Applicator
manual.
Figure 5.1
Gun and/
or
solenoid
manual.
C
Nord
son
Corpo
r
atoo
n 1993
All
Roghts
Rese
rved